Non Shrink Grout & Repair Materials

MC-Metal Grout

Non – shrink , Fluid High strength, meets Non- shrink requirements of CRD-C588-76

MC-Metal Grout is specially prepared , ready –to- use , non shrink grout. it is formulated for use at any consistency from fluid to damp – pack for grouting machines or plates requiring non- shrink , high –strength precision bearing , including machine bases subject to thermal movement. Complies with requirements of corps of engineers specification for non- shrink grout , CRD – C 588-76 .

Key technical properties
Mixing water per 25 kg bag4 L ± 10%
Approximate yield12 L per 25 kg
Approximate material requirement84 bags per m³
Compressive strength - 1 day250 kg/cm²
Key technical properties
Compressive strength - 3 days400 kg/cm²
Compressive strength - 7 days500 kg/cm²
Compressive strength - 28 days650 kg/cm²
Packaging25 kg moisture-resistant bag

Description

MC-Metal Grout is a specially prepared, ready-to-use, non-shrink grout for use from fluid to damp-pack consistency. It is intended for high-strength precision bearing beneath machines or plates, including machine bases subjected to thermal movement.

Where to use

Machinery and equipment requiring high strength, maximum bearing, impact resistance and non-shrink precision grouting. Crane rail plates and rolling, stamping, drawing or finishing mills in steel and aluminium industries. Paper-machine installations. Turbines, generators and centrifugal compressors. Applications where shrinkage must be eliminated to achieve maximum load and bearing transfer. Anchor bolts and rods.

Advantages

Hardens without bleeding, settlement or drying shrinkage when mixed, placed and cured at the appropriate consistency. Dense grout without gas-generating or air-release agents such as aluminium powder. Withstands thermal movement and cyclic heating/cooling and wetting/drying effects, according to the source. Ductile metallic aggregate provides higher strength and improved impact resistance under dynamic and repetitive loading. Develops strength without vertical confinement. Meets the source-referenced non-shrink requirements of CRD-C588-76.

Yield & strength development

Compressive strength - 3 days 400 kg/cm² Compressive strength - 7 days 500 kg/cm² Compressive strength - 28 days 650 kg/cm² Packaging 25 kg moisture-resistant bag

Precautions

The source specifies an approximate 7-40°C temperature range for the bedplate, foundation and grout. Do not use water in an amount or at a temperature that produces a flow of less than 20 seconds under the referenced CRD-C 79-77 test or causes bleeding / segregation.

Standards / source references

CRD-C588-76 CRD-C 79-77 flow reference, as stated by the source.